# Can you trust wrist heart rate during running intervals?

https://nurostride.com/en/articles/optical-heart-rate-running-intervals/

NuroStride

Published: 2026-11-06T15:31:35.735Z
Updated: 2026-11-06T15:31:35.735Z

A watch can agree well with a chest strap across a treadmill test without proving that every reading is right when the pace changes\. If the pulse trace looks flat at the start of an interval, keep that as an observation\. The trace alone cannot tell you whether your heart rate stayed flat or the sensor missed a change\.

## What the researchers compared

Oropesa and colleagues published their study online on 22 December 2025 in Applied Sciences\. Ten trained male runners and triathletes, aged 27 on average, took part\. This was a repeated comparison of sensors, not a trial of whether training with one sensor leads to better results\.

Across 14 indoor treadmill sessions, the researchers tested 16 optical monitors\. Each session paired two or three of those monitors with a Polar H9 electrical chest strap as the reference\. Seven sessions used an incremental test and seven used an interval test\. The interval test alternated four one\-minute bouts at 8 km/h with four one\-minute bouts at each participant’s maximal aerobic speed, then finished with one easier minute and one seated minute\. [Study methods](<https://mdpi-res.com/d_attachment/applsci/applsci-16-00126/article_deploy/applsci-16-00126.pdf#page=2>)

## What the agreement score leaves out

The study recorded heart rate each second, but the analysis used 20\-second averages\. Before averaging, the researchers removed blank or zero readings and readings more than 30% away from the chest strap\. They started the recordings by pressing the devices’ buttons together on a countdown\. The published comparison does not tell you how many seconds a particular device might lag at a pace change\.

In [Table 3](<https://mdpi-res.com/d_attachment/applsci/applsci-16-00126/article_deploy/applsci-16-00126.pdf#page=8>), the Polar Vantage V read 6 beats per minute lower than the strap on average over the interval test, 7 lower in the hard phase and 3 higher during cooldown\. Its agreement coefficient was 0\.935 overall and 0\.885 in the hard phase\. That coefficient summarises how well the paired measurements agree; it is not the percentage of correct readings\.

Missing readings are a separate issue\. In the same table, the Garmin Forerunner 35 had 6\.8% lost records and 12\.7% removed during cleaning\. An agreement score describes the pairs that made it into the analysis; it does not tell you whether the recording was complete\.

The distinction matters even if nothing is missing\. In a made\-up example, four equally spaced reference readings are 150, 150, 170 and 170 beats per minute\. Four watch readings are 150, 170, 150 and 170\. Both average 160, but the second and third readings disagree\. This is a calculation example, not a trace from the study or a model of how heart rate should respond\.

## How far the result travels

The results varied by monitor and test phase\. A single comparison in ten trained men indoors does not establish how your model or firmware behaves outdoors, or how well it measures people outside the sample\. The authors note that repeated readings came from the same runners; treating them as independent can make the estimates seem more precise\. They reported partial regional funding for one author and declared no conflicts of interest\.

## What to keep in your interval log

Keep the interval duration, pace or lap time, and how the effort felt next to the heart\-rate trace\. Record whether the trace came from the wrist or a chest strap\. If a segment is blank, leave it missing\. If it looks flat but you have no second measurement, mark it as uncertain; the study’s 30% exclusion relied on a simultaneous reference that your log may lack\.

A flat segment on its own is too little evidence to say you missed the intended effort\. The [long\-run threshold article](</en/articles/lactate-threshold-after-long-run/>) covers a separate question: even with a usable heart\-rate trace, a rise in pulse does not give you a new lactate\-threshold speed\.

Primary paper and Table 3 checked on 6 November 2026\. This explains one validation study; it is not a device ranking or medical advice\.

## Sources

- [Oropesa et al\. (2025): Concurrent validity of 16 optical heart\-rate monitors](<https://mdpi-res.com/d_attachment/applsci/applsci-16-00126/article_deploy/applsci-16-00126.pdf>) (2026-11-06T15:06:44.302Z)